Step-by-step N95 donning, the user seal check every time, safe doffing, and when to replace it.

N95: on, check, off. A respirator only works if it seals. Clean hands Before putting it on; Straps and nose Top strap high, mold nose clip; Seal check Breathe in and out; no leaks; Remove outside By the straps; then clean hands.

Putting it on

  1. Clean your hands.
  2. Check the respirator: straps intact, no damage, the model and size you were fit tested on.
  3. Cup it in your hand with the nosepiece at your fingertips and the straps hanging below.
  4. Place it under your chin with the nosepiece up.
  5. Pull the top strap over your head to rest high on the back of the head; pull the bottom strap to sit around the neck below the ears. Don't crisscross.
  6. Press the nose clip with the fingertips of both hands, moving down both sides of the nose, to mold it.

The user seal check: every single time

OSHA requires a user seal check each time you put on a tight-fitting respirator (1910.134(g)(1)(iii) and Appendix B-1). A seal check isn't a fit test; it confirms the respirator is seated correctly today.

  • Positive pressure check: cover the front with both hands and exhale gently. The respirator should bulge slightly with no air leaking around the edges.
  • Negative pressure check: cover the front and inhale sharply. It should pull slightly toward your face.
  • Air leaking around the nose? Readjust the nose clip. Around the edges? Adjust the straps. If you can't get a seal, don't enter: get a different size or model you've been fit tested on, or a PAPR.

Common failures: straps crossed or one strap used, the nose clip pinched to a point, glasses pushing the respirator off the nose, and facial hair under the seal.

During use

Don't touch or adjust the front. Don't pull it down to talk. If it becomes damaged, soiled or hard to breathe through, leave the room and replace it.

Taking it off

  1. Leave the patient room (respirators are removed outside the AIIR, after the door closes).
  2. Without touching the front, pull the bottom strap over your head, then the top strap.
  3. Discard it, or store it for reuse only if your facility's policy allows it.
  4. Clean your hands.